Difference between revisions of "Solar"

From Disorient wiki
Jump to: navigation, search
(Created page with "==D25== ==D24==")
 
 
Line 2: Line 2:


==D24==
==D24==
*Cell Leads: Power Jack, IceCream
*Solar at D24 consisted of 12x Canadian Solar 445W Mono-PERC Bifacial Panels (5.34 kWp) loaned from another camp not attending Burning Man 2024.
**These panels were connected in series to form a single string that was directly fed into a Sunny Boy SB-10000TL-US grid-tie inverter
**A 6awg power cable was connected between the inverter and the nearest distribution box, between the legs of the generator phase most utilized during the day.
**The total amperage reduction was about 18-22 amps across one phase.
*Solar Panels were mounted flat on top of two containers
*No cleaning of the panels was performed during the week, resulting in a steady reduction in power output day-to-day.
{| class="wikitable" style="margin:auto"
|+ Power production at D24
|-
! Date !! Peak Amps !! Peak Watts !! kWh Generated !! Est. Fuel Saved (Gal) !! Notes
|-
| Sunday || 5 || 1040 || 1.1 || 0.202266356 || Connected at ~5pm
|-
| Monday || 14.5 || 3016 || 24.2 || 4.449859823
|-
| Tuesday || 14 || 2912 || 21.8 || 4.008551411
|-
| Wednesday || 11 || 2288 || 18.8 || 3.456915896
|-
| Thursday || 10 || 2080 || 18.3 || 3.364976643
|-
| Friday || 9 || 1872 || 17.3 || 3.181098138
|-
| Saturday || 9 || 1872 || 17.1 || 3.144322437
|-
| Sunday || 8 || 1664 || 7.1 || 1.305537386 || Disconnected at ~11:30am
|-
| TOTAL || || || 125.7 || 23.11352809
|}

Latest revision as of 11:12, 10 August 2025

D25

D24

  • Cell Leads: Power Jack, IceCream
  • Solar at D24 consisted of 12x Canadian Solar 445W Mono-PERC Bifacial Panels (5.34 kWp) loaned from another camp not attending Burning Man 2024.
    • These panels were connected in series to form a single string that was directly fed into a Sunny Boy SB-10000TL-US grid-tie inverter
    • A 6awg power cable was connected between the inverter and the nearest distribution box, between the legs of the generator phase most utilized during the day.
    • The total amperage reduction was about 18-22 amps across one phase.
  • Solar Panels were mounted flat on top of two containers
  • No cleaning of the panels was performed during the week, resulting in a steady reduction in power output day-to-day.
Power production at D24
Date Peak Amps Peak Watts kWh Generated Est. Fuel Saved (Gal) Notes
Sunday 5 1040 1.1 0.202266356 Connected at ~5pm
Monday 14.5 3016 24.2 4.449859823
Tuesday 14 2912 21.8 4.008551411
Wednesday 11 2288 18.8 3.456915896
Thursday 10 2080 18.3 3.364976643
Friday 9 1872 17.3 3.181098138
Saturday 9 1872 17.1 3.144322437
Sunday 8 1664 7.1 1.305537386 Disconnected at ~11:30am
TOTAL 125.7 23.11352809