Difference between revisions of "Solar"
From Disorient wiki
(Created page with "==D25== ==D24==") |
Power Jack (talk | contribs) (→D24) |
||
| Line 2: | Line 2: | ||
==D24== | ==D24== | ||
*Cell Leads: Power Jack, IceCream | |||
*Solar at D24 consisted of 12x Canadian Solar 445W Mono-PERC Bifacial Panels (5.34 kWp) loaned from another camp not attending Burning Man 2024. | |||
**These panels were connected in series to form a single string that was directly fed into a Sunny Boy SB-10000TL-US grid-tie inverter | |||
**A 6awg power cable was connected between the inverter and the nearest distribution box, between the legs of the generator phase most utilized during the day. | |||
**The total amperage reduction was about 18-22 amps across one phase. | |||
*Solar Panels were mounted flat on top of two containers | |||
*No cleaning of the panels was performed during the week, resulting in a steady reduction in power output day-to-day. | |||
{| class="wikitable" style="margin:auto" | |||
|+ Power production at D24 | |||
|- | |||
! Date !! Peak Amps !! Peak Watts !! kWh Generated !! Est. Fuel Saved (Gal) !! Notes | |||
|- | |||
| Sunday || 5 || 1040 || 1.1 || 0.202266356 || Connected at ~5pm | |||
|- | |||
| Monday || 14.5 || 3016 || 24.2 || 4.449859823 | |||
|- | |||
| Tuesday || 14 || 2912 || 21.8 || 4.008551411 | |||
|- | |||
| Wednesday || 11 || 2288 || 18.8 || 3.456915896 | |||
|- | |||
| Thursday || 10 || 2080 || 18.3 || 3.364976643 | |||
|- | |||
| Friday || 9 || 1872 || 17.3 || 3.181098138 | |||
|- | |||
| Saturday || 9 || 1872 || 17.1 || 3.144322437 | |||
|- | |||
| Sunday || 8 || 1664 || 7.1 || 1.305537386 || Disconnected at ~11:30am | |||
|- | |||
| TOTAL || || || 125.7 || 23.11352809 | |||
|} | |||
Latest revision as of 11:12, 10 August 2025
D25
D24
- Cell Leads: Power Jack, IceCream
- Solar at D24 consisted of 12x Canadian Solar 445W Mono-PERC Bifacial Panels (5.34 kWp) loaned from another camp not attending Burning Man 2024.
- These panels were connected in series to form a single string that was directly fed into a Sunny Boy SB-10000TL-US grid-tie inverter
- A 6awg power cable was connected between the inverter and the nearest distribution box, between the legs of the generator phase most utilized during the day.
- The total amperage reduction was about 18-22 amps across one phase.
- Solar Panels were mounted flat on top of two containers
- No cleaning of the panels was performed during the week, resulting in a steady reduction in power output day-to-day.
| Date | Peak Amps | Peak Watts | kWh Generated | Est. Fuel Saved (Gal) | Notes |
|---|---|---|---|---|---|
| Sunday | 5 | 1040 | 1.1 | 0.202266356 | Connected at ~5pm |
| Monday | 14.5 | 3016 | 24.2 | 4.449859823 | |
| Tuesday | 14 | 2912 | 21.8 | 4.008551411 | |
| Wednesday | 11 | 2288 | 18.8 | 3.456915896 | |
| Thursday | 10 | 2080 | 18.3 | 3.364976643 | |
| Friday | 9 | 1872 | 17.3 | 3.181098138 | |
| Saturday | 9 | 1872 | 17.1 | 3.144322437 | |
| Sunday | 8 | 1664 | 7.1 | 1.305537386 | Disconnected at ~11:30am |
| TOTAL | 125.7 | 23.11352809 |